RFoG Extender |
||||||||||
Outdoor Mounted EDFA with Return Receiver and Transmitter |
||||||||||
Extend the Reach of your RFoG system |
||||||||||
|
||||||||||
Specifications in Housing |
||||||||||
Parameter | Test Conditions |
Units |
Notes |
EDFA |
||||||
Output Power | – |
dBm |
– |
13 to 26 |
||||||
Wavelength | – |
nm |
– |
1530-1560 |
||||||
Max Input | – |
dBm |
– |
10 |
||||||
Minimum Input | – |
dBm |
-12 |
|||||||
Noise Figure @ Power Level |
13-16 dBm out |
17to 21 dBm out |
22 to 26 dBm out |
|||||||
@ 0 dBm input |
≤ 4.5 |
≤ 5 |
≤ 5.3 |
|||||||
@ 6 dBm input |
≤ 5.5 |
≤ 6 |
≤ 6.5 |
|||||||
Output Stability 0-65°C | – |
dB |
±0.3 |
|||||||
Output Stability -40-65°C | – |
dB |
±0.6 |
|||||||
Polarization |
dB |
<0.2 |
||||||||
Polarization Mode Dispersion |
dB |
<0.5 |
||||||||
Reflection Loss | – |
dB |
– |
> 40 |
||||||
Power |
Watts |
> 50 |
||||||||
Voltage |
VAC |
40-90 |
||||||||
Working Temperature | – |
°C |
– |
-40 to +60 |
||||||
LCD Display Temperature |
|
°C |
1 |
0 to +60 |
|
|||||
1310/1550 Isolation |
|
dB |
≥ 60 |
|
||||||
Return Receiver and Transmitter |
||||||||||
Reference Frequencies | – |
MHz |
5-40 |
|||||||
Output Light Level | – |
dBm |
– |
3 |
||||||
Input Light | For 30 dB C/N minimum |
dBm |
-26 |
|||||||
AGC | 10 dB input change |
dB |
– |
± 1 |
||||||
Crosstalk between Receivers |
dB |
– |
≥ 60 |
|||||||
Indicator Light Red | 3 |
dBm |
2 |
-28 |
||||||
Test Point Transmitter | 1 mW |
V |
1 |
|||||||
Test Point Receiver | -20 dBm input |
V |
– |
1 |
||||||
Notes:
- The LCD readout for the EDFA operational parameters only works above 0° C
- The red alarm light will turn on at -28 dBm. It will return to Green after the level has increased to -26 dBm. There is approximately a 3 second delay to enable capture of the bursting nature of the incoming light. If there is no data transmitted in over 3 seconds the red light will come on.
Available now from stock to 4 weeks
Contact: 877-825-6409
1248 Highway 501 Business
Conway SC 29526