Magnavox/Phillips 1 GHz 6LE Type PowerMiser™
Download pdf spec sheet |
4CLE1000L 1 GHz Line Extender |
||||||||
LOW CURRENT 410 mA |
||||||||
![]() |
Drop In replacement for Magnavox/Philips 5 & 6LE PowerMiser™
|
|||||||
Specifications in Housing |
||||||||
Parameter | Test Conditions |
Units |
Notes |
Forward |
Reverse |
|||
Technology | – |
– |
– |
GaAs |
GaAs |
|||
Bandwidth | – |
MHz |
– |
54-1003 |
5-40 |
|||
Response Flatness | – |
dB |
– |
+/-0.75 |
+/-0.5 |
|||
Minimum Full Gain | – |
dB |
1 |
39* |
20 |
|||
Operational Gain | – |
dB |
– |
38 |
19 |
|||
Slope Built in | Cable Equivalent |
dB |
|
22 |
0 |
|||
|
|
|
|
|||||
Input Test Points | – |
dB |
– |
-20 +/-1 |
-20 +/-1 |
|||
Output Test Points | – |
dB |
4 |
-20 +/-1 |
External on housing |
|||
Input Return Loss | Freq | 5-40 MHz |
dB |
2 |
– |
16 |
||
54-1003 MHz |
16 |
|||||||
Output Return Loss | Freq | 5-40 MHz |
dB |
|
– |
16 |
||
54-1003 MHz |
16 |
|||||||
Loop Isolation | – |
dB |
– |
> 30 |
||||
DC Current Draw (max) | @24 Volts DC |
mA |
– |
410 |
||||
AC Current Draw (max) | 90 VAC |
mA |
– |
160 |
||||
60 VAC |
200 |
|||||||
50 VAC |
230 |
|||||||
40 VAC |
290 |
|||||||
Noise Figure | – |
dB |
– |
7 |
4.5 |
|||
Distortion Measurements @ rated loading |
||||||||
Reference Frequencies | – |
MHz |
|
55/550/870/1GHz |
T7-T12 |
|||
Output Levels | – |
dBmV |
– |
35/44/49.5/52 |
36 |
|||
Channel Loading | – |
NTSC |
3 |
79 + 450 MHz digital or equalivlent |
4 channels |
|||
Composite Triple Beat | – |
dBc |
– |
74 |
86 |
|||
Composite Second Order |
dBc |
– |
77 |
86 |
||||
Carrier to Noise |
dB |
– |
60 |
74 |
||||
Cross Modulation |
dBc |
– |
74 |
84 |
||||
Notes:
1. Factory alignment with 22 dB cable equivalent, and 17 dB of flat gain. 42 dB gain version available
2. All return loss measurements made with 0 dB pads and a #18 gauge wire jumpers in place of the equalizers.
3. Distortion measurements made with 79 analog channels and 450 MHz digital channels or equalivlent noise running 6 dB down from an analog equivalent.
4. Resistive -20 dB test points on the housing
5. Reverse sweep can be inserted using the output test point of the restive test point on the housing
Recorded Sweep
Available now from stock to 4 weeks
Contact: 4Cable TV Inc. 877-825-6409
1248 Highway 501 Business
Conway SC 29526