CCor Type E-7 series 1 GHz PowerMiser™
4CE10XXL 1 GHz Line Extender |
||||||||
LOW CURRENT 435 mA |
||||||||
Drop In replacement for CCor E-7 series PowerMiser™
|
||||||||
Specifications in Housing |
||||||||
Parameter | Test Conditions |
Units |
Notes |
Forward |
Reverse |
|||
Technology | – |
– |
– |
GaAs |
GaAs |
|||
Bandwidth | – |
MHz |
– |
54-1003 |
5-40 |
|||
Response Flatness | – |
dB |
– |
+/-0.75 |
+/-0.5 |
|||
Minimum Full Gain | – |
dB |
1 |
41 |
20 |
|||
Operational Gain | – |
dB |
– |
36 |
19 |
|||
Slope Built in | Cable Equivalent |
dB |
|
22 |
0 |
|||
AGC | ± 3 Change |
dB |
7 |
± .5 Change |
NA |
|||
Input Test Points | – |
dB |
– |
-20 +/-1 |
-20 +/-1 |
|||
Output Test Points | – |
dB |
5 |
-20 +/-1 |
External on housing |
|||
Input Return Loss | Freq | 5-40 MHz |
dB |
2 |
– |
16 |
||
54-1003 MHz |
16 |
|||||||
Output Return Loss | Freq | 5-40 MHz |
dB |
|
– |
16 |
||
54-1003 MHz |
16 |
|||||||
Loop Isolation |
– |
dB |
– |
> 30 |
|
|||
DC Current Draw (max) |
@24 Volts DC |
mA |
– |
435 |
|
|||
AC Current Draw (max) |
90 VAC |
mA |
– |
170 |
|
|||
60 VAC |
210 |
|
||||||
50 VAC |
245 |
|
||||||
40 VAC |
307 |
|
||||||
Noise Figure |
– |
dB |
– |
7 |
4.5 |
|
||
Distortion Measurements @ rated loading |
|
|||||||
Reference Frequencies |
– |
MHz |
|
55/550/870/1GHz |
T7-T12 |
|
||
Output Levels |
– |
dBmV |
– |
35/44/49.5/52 |
36 |
|
||
Channel Loading |
– |
NTSC |
3 |
79 + 450 MHz digital or equalivlent |
4 channels |
|
||
Composite Triple Beat |
– |
dBc |
– |
74 |
86 |
|
||
Composite Second Order |
|
dBc |
– |
77 |
86 |
|
||
Carrier to Noise |
|
dB |
– |
60 |
74 |
|
||
Cross Modulation |
|
dBc |
– |
74 |
84 |
|
||
|
|
|
|
|
|
|
|
|
Notes:
1. Factory alignment with 22 dB cable equivalent, and 17 dB of flat gain. 42 dB gain version available
2. All return loss measurements made with 0 dB pads and a #18 gauge wire jumpers in place of the equalizers.
3. Distortion measurements made with 79 analog channels and 450 MHz digital channels or equalivlent noise running 6 dB down from an analog equivalent.
4. Resistive -20 dB test points on the housing
5. Reverse sweep can be inserted using the output test point of the restive test point on the housing
6. Available in a field configurable 1, 2 or 3 output with plug-in splitters and Directional couplers
7. BODE Control
Recorded Sweep
Available now from stock to 4 weeks
Contact: 4Cable TV Inc. 877-825-6409
1248 Highway 501 Business
Conway SC 29526