650 MHz Mag Trunk
Download pdf spec sheet |
5T650BODE 650 MHz Trunk Amplifier |
|||||||
..
|
Drop In replacement for Magnavox/Philips 4/5/6/8T When Operated with 4Cable’s CCD it will AGC from aDigital or an Analog Channel Operational Gain 35 dB – Low Distortion 100% New Board Low Noise Figure 6 dB 40% Less current than a Feedforward Interstage EQ’s and Pads for maximum flexibility GaAs FET Technology BODE Gain control for single pilot operation |
||||||
Specifications in Housing |
|||||||
Parameter | Test Conditions |
Units |
Notes |
Forward |
|||
Technology | – |
– |
– |
GaAs FET PD |
|||
Bandwidth | – |
MHz |
– |
54-650 |
|||
Response Flatness | – |
dB |
– |
+/-0.25 |
|||
Minimum Full Gain | – |
dB |
1 |
38 |
|||
Operational Gain | – |
dB |
– |
35 |
|||
Slope | Cable Equivalent |
dB |
10 |
||||
Input Return Loss | Freq | 54-650 MHz |
dB |
2 |
16 |
||
Output Return Loss | Freq | 54-650 MHz |
dB |
16 |
|||
DC Current Draw (max) | – |
mA |
– |
680 |
|||
Noise Figure | – |
dB |
– |
6 |
|||
Distortion Measurements @ rated loading |
|||||||
Reference Frequencies | – |
MHz |
55/550/650 |
||||
Output Levels | – |
dBmV |
– |
32/42/44 |
|||
Channel Loading | – |
NTSC |
3 |
77 + digital above 550 MHz |
|||
Composite Triple Beat | – |
dBc |
– |
79 |
|||
Composite Second Order |
dBc |
– |
76 |
||||
Carrier to Noise |
dB |
– |
65 |
||||
Cross Modulation |
dBc |
– |
85 |
||||
Notes:
1. Factory alignment with 10dB cable equivalent and 28 dB of flat gain.
2. All return loss measurements made with 0 dB pads and a #18 gauge wire jumpers in place of the equalizers.
3. Distortion measurements made with 77 analog channels and digital channels running 6 dB down from an analog equivalent.
4. A 5 db Interstage EQ is recommended for optimum field operation
5. 750 MHz version available on special order 1 dB higher gain and distortions will be 1 dB lower
Available now from stock to 4 weeks
Contact: 4Cable TV Inc. 877-825-6409
1248 Highway 501 Business
Conway SC 29526