Go Back Download pdf spec sheet

 

 

CCD*** Digital  Control Module

 

 

.

.

 

 

Works with 5T650BODE Trunk Amp for BODE Operation from Single Pilot

Works with a Digital or Analog Channel

First Operational Digital Keyed AGC

Helical Filters

 

 

 

Specifications in Housing

 

Parameter

Test Conditions

Units

Notes

Forward

 

 

Modulation

-

-

1

Analog or Digital

 

Frequency

-

MHz

-

As Ordered

 

Pilot Levels

-

dB

-

 

 

         Analog

At CCD input Pilot 505.25

dBmV

2

18

 

         Digital

Pilot at 507 MHz

dBmV

3

12

 

Recovery Performance

± 3

dB

 

 

 

       Constant Temperature

 

dB

 

± 0.75

 

       -40 F to +140 F

 

dB

 

± 1

 

DC Current Draw (max)

-

mA

-

80

 

 

 

 

 

 

 

 

 

               

Notes:

1.                   Digital levels are assumed to be 6 dB down from Analog

2.                   All units are aligned for operation with an Analog channel with a 3 dB pad in the unit..

3.                   For operation with a digital channel the 3 dB pad must be replaced with a 0 dB pad.

 