Go Back Download pdf spec sheet

 

  4CLE1000L  1 GHz Line Extender

 

LOW CURRENT 410 mA 

 

Drop In replacement for Magnavox/Philips 5 & 6LE

PowerMiser™

  • High Gain 39 dB
  • ½ the Current Draw of Conventional  Amps
  • $8.00 per year average savings on Electric
  • Low Noise Figure 7 dB
  • High Output  50 dBmV
  • Built in Return Amplifier
  • Standard Interstage EQ’s and Pads
  • Plug in Diplexers for future split changes
  • 100% New Construction with 90 Volt Power Supply
  • Breakthrough Low Current Technology

 

 

Specifications in Housing

 

Parameter

Test Conditions

Units

Notes

Forward

Reverse

 

Technology

-

-

-

GaAs

GaAs

 

Bandwidth

-

MHz

-

54-1003

5-40

 

Response Flatness

-

dB

-

+/-0.75

+/-0.5

 

Minimum Full Gain

-

dB

1

39*

20

 

Operational Gain

-

dB

-

38

19

 

Slope Built in

Cable Equivalent

dB

 

22

0

 

 

 

 

 

 

 

 

Input Test Points

-

dB

-

-20 +/-1

-20 +/-1

 

Output Test Points

-

dB

4

-20 +/-1

External on housing

 

Input Return Loss

Freq

5-40 MHz

dB

 2

-

16

 

54-1003 MHz

16

 

Output Return Loss

Freq

5-40 MHz

dB

 

-

16

 

54-1003 MHz

16

 

Loop Isolation

-

dB

-

> 30

 

DC Current Draw (max)

@24 Volts DC

mA

-

410

 

AC Current Draw (max)

90 VAC

mA

-

160

 

60 VAC

200

 

50  VAC

230

 

40  VAC

290

 

Noise Figure

-

dB

-

7

4.5

 

Distortion Measurements @ rated loading 

 

Reference Frequencies

-

MHz

 

55/550/870/1GHz

T7-T12

 

Output Levels

-

dBmV

-

35/44/49.5/52

36

 

Channel Loading

-

NTSC

3

79 + 450 MHz  digital or equalivlent

4 channels

 

Composite Triple Beat

-

dBc

-

74

86

 

Composite Second Order

 

dBc

-

77

86

 

Carrier to Noise

 

dB

-

 60

74

 

Cross Modulation

 

dBc

-

74

84

 

 

 

 

 

 

 

 

 

                 

www.4cable.tv

 Notes:

1.                   Factory alignment with 22 dB cable equivalent, and 17 dB of flat gain.  42 dB gain version available

2.                   All return loss measurements made with 0 dB pads and a  #18 gauge wire jumpers in place of the equalizers.

3.                   Distortion measurements made with 79 analog channels and 450 MHz  digital channels or equalivlent noise running 6 dB down from an analog equivalent. 

4.                   Resistive -20 dB test points on the housing

5.                   Reverse sweep can be inserted using the output test point of the restive test point on the housing

 

Recorded Sweep

 

Available now from stock to 4 weeks

 

 

Contact:           4Cable TV Inc.                                  843-365-4938

1256 Highway 501 Business

Conway SC 29526

www.4cable.tv                         sales@4cable.tv

free web counter
free web counter