4CE10XXL 1
GHz Line Extender
|
|
LOW
CURRENT 435 mA
|
|
|
|
Drop In replacement for CCor E-7 series
PowerMiser™
- High Gain 40 dB
- ½ the Current
Draw of Conventional Amps
- $8.00 per year average savings on Electric
- Low Noise Figure 7 dB
- High Output 52 dBmV
- Built in Return Amplifier
- Standard Interstage EQ’s and Pads
- Plug in Diplexers for future split changes
- 100% New Construction with 90 Volt Power Supply
- Breakthrough Low Current Technology
|
|
|
Specifications in Housing
|
|
|
Parameter
|
Test
Conditions
|
Units
|
Notes
|
Forward
|
Reverse
|
|
|
Technology
|
-
|
-
|
-
|
GaAs
|
GaAs
|
|
|
Bandwidth
|
-
|
MHz
|
-
|
54-1003
|
5-40
|
|
|
Response
Flatness
|
-
|
dB
|
-
|
+/-0.75
|
+/-0.5
|
|
Minimum Full Gain
|
-
|
dB
|
1
|
41
|
20
|
|
Operational Gain
|
-
|
dB
|
-
|
36
|
19
|
|
Slope Built in
|
Cable
Equivalent
|
dB
|
|
22
|
0
|
|
AGC
|
±
3 Change
|
dB
|
7
|
± .5 Change
|
NA
|
|
Input Test Points
|
-
|
dB
|
-
|
-20 +/-1
|
-20 +/-1
|
|
Output Test Points
|
-
|
dB
|
5
|
-20 +/-1
|
External on housing
|
|
Input Return Loss
|
Freq
|
5-40 MHz
|
dB
|
2
|
-
|
16
|
|
|
54-1003 MHz
|
16
|
|
Output Return Loss
|
Freq
|
5-40 MHz
|
dB
|
|
-
|
16
|
|
|
54-1003 MHz
|
16
|
|
Loop Isolation
|
-
|
dB
|
-
|
> 30
|
|
DC Current Draw (max)
|
@24 Volts DC
|
mA
|
-
|
435
|
|
AC Current Draw (max)
|
90 VAC
|
mA
|
-
|
170
|
|
|
60 VAC
|
210
|
|
|
50 VAC
|
245
|
|
|
40 VAC
|
307
|
|
Noise Figure
|
-
|
dB
|
-
|
7
|
4.5
|
|
|
Distortion Measurements @ rated loading
|
|
Reference Frequencies
|
-
|
MHz
|
|
55/550/870/1GHz
|
T7-T12
|
|
Output Levels
|
-
|
dBmV
|
-
|
35/44/49.5/52
|
36
|
|
Channel Loading
|
-
|
NTSC
|
3
|
79 + 450 MHz digital or equalivlent
|
4 channels
|
|
Composite Triple Beat
|
-
|
dBc
|
-
|
74
|
86
|
|
|
Composite
Second Order
|
|
dBc
|
-
|
77
|
86
|
|
|
Carrier to Noise
|
|
dB
|
-
|
60
|
74
|
|
Cross Modulation
|
|
dBc
|
-
|
74
|
84
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
www.4cable.tv
Notes:
1.
Factory alignment with 22 dB
cable equivalent, and 17 dB of flat gain. 42 dB gain version available
2.
All return loss measurements
made with 0 dB pads and a #18 gauge wire jumpers in place of the equalizers.
3.
Distortion measurements made
with 79 analog channels and 450 MHz digital channels or equalivlent noise running
6 dB down from an analog equivalent.
4.
Resistive -20 dB test points
on the housing
5.
Reverse sweep can be inserted
using the output test point of the restive test point on the housing
6.
Available in a field
configurable 1, 2 or 3 output with plug-in splitters and Directional couplers
7.
BODE Control
Recorded Sweep